Tuesday, October 5, 2010

Repair Locked SAMSUNG Monitor

Immediately, I share here will be how to repair / Service Monitor SAMSUNG, damage to the monitor itself is the emergence of the display control lock / locked at the time the monitor is turned on.

Likewise, when the VGA cable from the monitor connected to the PC nothing happened what / no response: (. After the check was coming out of the IC voltage regulator 7805 experiencing leakage to the measured voltage of 7 volts. For more details please see the picture:
monitor samsung unlock Service Monitor SAMSUNG Terkunci
Display on CRT monitor displays text Unlocked
cek tegangan regulator Service Monitor SAMSUNG Terkunci
Check the location of the regulator IC 7805 to IC MICOM
tegangan regulator 7805 Service Monitor SAMSUNG Terkunci
Measure the output voltage regulator IC
pengukuran avometer Service Monitor SAMSUNG Terkunci
When measured more than 5 volts, replace / replace IC 7805.
 Service Monitor SAMSUNG Terkunci
Regulator IC 7805

A good idea to check also the conditions that are beyond the range of IC / after the IC is revoked, is to ensure that the voltage over 7 volts which causes the samsung monitor is not damaged from the other components of the Monitor. We can use a simple circuit to check:
cek IC regulator 7805 300x140 Service Monitor SAMSUNG Terkunci 
Input leg is leg number 1 from the left when we look at IC from the front, ground is the foot of No. 2, while the output is the foot of No. 3.
Unfortunately I do not have a schematic of this monitor so it can not show directly where the exact location of this IC on the circuit, but I think with the instructions above picture can be quite clearly not